distributors
Find a Bioreset® distributor in your area.
HEADQUARTER

ITALY
Amira srl
Via Vecchia Milanese 12
20844 Triuggio (MB)
PH. +39 0362 528178
Fax +39 0362 919596
info@amirasrl.com
www.amirasrl.com



EUROPE

AUSTRIA / GERMANY
PMT PARTIKEL MESSTECHNIK GMBH
PH. +49 (0) 7033 / 53740
INFO@PMT.EU
www.PMT.EU

DENMARK
SCANBUR DENMARK
PH. +45 5686 5600
INFO@SCANBUR.COM
www.SCANBUR.COM

Brookhaven Instruments AB
PH. +45 2970 39 42
info@brookhaven.se
www.brookhaven.se

EST EUROPE
ECM ECO MONITORING, A.S.
PH. +421 2 43429417
ECM@ECM.SK
www.ECOMONITORING.COM

Finland
SCANBUR FINLAND
PH. +358 40 583 2999
ORDERS-FIN@SCANBUR.COM
www.SCANBUR.COM

NORWAY
SCANBUR NORWAY
PH. +47 6706 2920
INFO-NO@SCANBUR.COM
www.SCANBUR.COM

POLAND
UNI-EXPORT INSTRUMENTS POLSKA
PH. +48 (22) 771 86 01
UNIEXPORT@UNI-EXPORT.PL
WWW.UNI-EXPORT.PL

SPAGNA
INSTRUMENTACIÓN ANALÍTICA, S.A.
PH. +34 91 358 88 79
INFO@INSTRU.ES
www.INSTRU.ES

SWEDEN
SCANBUR SWEDEN
PH. +46 8 594 767 80
INFO-SE@SCANBUR.COM
www.SCANBUR.COM

Brookhaven Instruments AB
PH. +45 2970 3942
kim@brookhaven.se
www.brookhaven.se

SWITZERLAND
LOGICAIR SA
PH. +41 32 835 50 89
BIORESET@LOGICAIR.CH
www.LOGICAIR.CH

PMT SCHWEIZ AG
PH. +41 44 994 70 05
WELCOME@PMT-AG.CH
www.pmt-ag.c

UNITED KINGDOM
PMT (GB) LIMITED
PH. +44 16 84 31 29 51
INFO@PMTGB.COM
www.PMTGB.COM

SYCHEM LTD
PH. +44 (0)845 644 6824
SALES@SYCHEM.CO.UK
www.SYCHEM.CO.UK

AMERICAS

ARGENTINA
OPYR
PH. +54 (11) 4116 0591 / 0592
VENTAS@OPYR.COM.AR
www.OPYR.COM.AR

BRASIL
PARTITEC
PH. +55 11 4087 0497
PARTITEC@PARTITEC.COM.BR
www.PARTITEC.COM.BR

USA
PMT (USA) LLC
PH. +1 720 3404752
INFO@PMT-US.COM
www.PMT-US.COM
ASIA-PACIFIC

INDIA
SVAN ANALYTICAL INSTRUMENTS PVT LTD
PH. +91 86 55320397 / 86 52227877
EN95@SVAN.IN
www.SVAN.IN

JAPAN
DENCOM CORPORATION
PH. +81 44 201 1418
sales@dencomjapan.com
www.dencomjapan.com

SINGAPORE
APEX INTERLINK
SALES@APEXINTERLINK.COM

SOUTH KOREA
CRENVITEK CO., LTD.
PH. +82 31 8027 2121
JCJAE@CRENVIS.COM
www.crenvitek.com

BIORESETCOMBO

SEPARATE ROOMS BIODECONTAMINATED SIMULTANEOUSLY, EVEN IF LOCATED ON DIFFERENT LEVEL.

TOP CUSTOMISATON
AN INNOVATIVE SOLUTION, DESIGNED AND CUSTOMISED FOR THE BIODECONTAMINATION OF COMPLEX ROOMS AND VOLUMES WITH FAST AND EFFECTIVE CYCLES.

HOW IT WORKS
A PIPING SYSTEM WITH MULTIPLE INJECTION POINTS, COMBINED WITH THE USE OF BIORESET GENERATORS, ALLOWS THE HOMOGENEOUS DISTRIBUTION OF THE RIGHT AMOUNT OF DECONTAMINATING AGENT IN DIFFERENT AREAS SIMULTANEOUSLY. FIXED INSTALLATION OF THE GENERATORS SIMPLIFIES THE REPEATABILITY OF THE VALIDATED CYCLES.

TURNKEY SOLUTION
OUR TEAM OF EXPERT ENGINEERS AND BIOLOGISTS IS ABLE TO FACE AND SOLVE EVEN THE MOST CHALLENGING SITUATIONS, OFFERING A CONSULTING APPROACH FOR THE DIFFERENT PHASES OF THE PROJECT AND PROVIDING A TURNKEY SOLUTION.


DOWNLOAD PDF


WRITE US

BIORESET, THE MOBILE GENERATOR FOR ABSOLUTE BIODECONTAMINATION H2O2 V PHASE.

Rapid, effective, incomparable!

BioReset is a bio-decontamination system that uses Vapour-Phase Hydrogen Peroxide as a cold sterilising agent.

BioReset is mainly used to remove the airborne and surface
microbiological contamination in controlled or classified environments
for pharmaceutical, biomedical, biotechnological, animal care and
in any other environment sensitive to microbiological contamination.

BioReset works with efficiency and speed, no pre-conditioning of the
environment is needed, uses Hydrogen Peroxide (H2O2), and requires
little maintenance. Cost savings due to speed of cycles and less need
for costly consumables make BioReset the most convenient solution
on the market.

Vapour-phase H2O2 advantages

Proved efficiency
Indicated for a wide range of microorganisms and viruses, Bioreset uses the H2O2 in vapour phase to guarantee a uniform distribution able to reach the most difficult areas of the environment. It is capable of a 6 Log reduction on all exposed surfaces.

Excellent compatibility
Hydrogen Peroxide has chemical-physical characteristics that are compatible with many materials such as metals, plastics, elastomers and all electronic devices. The vapour-phase H2O2 limits the formation of potentially corrosive liquid.

Unbeatable speed
The low working temperature and the efficiency of the vapour-phase H2O2 allow a cycle time that is attractive to a wide range of applications, and offers a rapid recovery of the production activity.

SAFE TO USE
It is not dangerous for staff and is safe for the environment. At the end of each bio-decontamination cycle it catalyses into water and oxygen, with no pollution risk.

Removable microorganisms

It is lethal to all known microorganisms, chemically active against spores with proven kill rates, easy to handle and safer to use than other gaseous agents.

BACTERIA
Bacillus, Clostridium, Mycobacterium, Listeria, Lactobacillus, Enterococcus, Staphylococcus, Enterobacter, Escherichia, Klebsiella, Serratia, Salmonella, Yersinia, Legionella, Acietobacter, Pseudomonas, Acholeplasma.

VIruses
Herpesviridae, Iridoviridae, Poxviridae, Adenoviridae, Orthomyxoviridae, Paramyxoviridae, Parvoviridae, Rhabdoviridae, Flaviviridae, Arenaviridae, Caliciviridae, Picornaviridae, Reoviridae.

FUNGI
Alternaria, Aspergillus, Blastomyces, Candida, Coccidioides, Histoplasma, Penicillium.

bioreset, THREE SIZEs. unlimited applications.
AND FDA 21 CFR PART 11 COMPLIANT.

AUTOMATIC PROCESS
POSSIBILITY TO AUTOMATICALLY CONFIGURE AND ADJUST THE PROCESS THANKS TO THE REACTIVE FEEDBACK OF THE INTEGRATED T/RH PROBE.

REPORT IN REAL TIME
POSSIBILITY TO EXPORT REPORTS IN PDF FORMAT OR PRINT THEM ON A NETWORK DEVICE TO GET IMMEDIATE VISIBILITY OF THE PROCESSES OUTCOME.

USER FRIENDLY
INTUITIVE AND EASY TO USE, IT ALLOWS THE OPERATOR TO SIMPLY INTERACT WITH THE MACHINE FOR SET UP AND PROCESS CONTROL.

HIGH-TECH DESIGN AND KNOW-HOW
‘MADE IN ITALY’

DEVELOPED AND IMPLEMENTED BY OUR ENGINEERING TEAM, BASED ON FIELD EXPERTISE AND CONTINUOUS R&D ACTIVITY, TO MEET CUSTOMERS’ NEEDS AND WITH GREAT ATTENTION TO GRAPHIC LAYOUT.

FDA 21 CFR PART 11: EASY TO BE COMPLIANT
MANAGING DATA SECURITY IN ACCORDANCE WITH FDA 21 CFR PART 11 IS NO MORE A CHALLENGE. THE SOFTWARE MEETS THE MOST STRINGENT CONTROL REQUIREMENTS AND GUIDELINES TO ENSURE TRACEABILITY AND INTEGRITY OF ARCHIVED DATA.

DOWNLOAD PDF
a complete service package including sales and technical support.

On-site bio-decontamination service, to reset the environmental sterility or prove the efficiency of the instrument if the customer is interested in purchasing.
 
The validation service is executed with a chemical indicator map to verify the correct distribution and a microbiological indicator map (with Bacillus Stearothermophilus spores) to prove the cycle efficacy. Biological indicators are incubated at 55 °C as described in the international guidelines.
 
The monitoring service is executed with appropriate instrumentation, to check the residual Hydrogen Peroxide based on international guidelines of < 1 ppm.
 
Supply of consumables.
 
All Bioreset models are accompanied with protocols for IQ/OQ and development of bio-decontamination cycles with chemical and microbiological map. Also PQ is available on request.
ALL RIGHTS RESERVED ©
® REGISTERED TRADEMARK
AMIRA SRL 20844 TRIUGGIO (MB), ITALY   |   VIA VECCHIA MILANESE 12   |   PH. 0039 0362 528178   |   FAX 0039 0362 919596
  P. IVA 04100800962   |   REA N°1725870   |   C.C.I.A.A. N°04100800962